美國(guó)AccuMAX SPECTROLINE XS-555/I可見(jiàn)光傳感器,白光照度檢測(cè)
更新時(shí)間:2024-10-19
訪(fǎng)問(wèn)量:3400
廠商性質(zhì):代理商
生產(chǎn)地址:美國(guó)
美國(guó)AccuMAX SPECTROLINE XS-555/I可見(jiàn)光傳感器,白光照度檢測(cè)
傳感器型號(hào)XS-555/I,外形尺寸(長(zhǎng)x寬x高):7.6cmx5.1cmx2.2cm ;凈重:68克
檢測(cè)可見(jiàn)光照度(白光照度),中心峰值波長(zhǎng):555nm,測(cè)量量程:0-5300 lux(勒克斯) ;0-500 fc(英尺燭光)。
SPECTROLINE AccuMAX™ 系列數(shù)字式黑白兩用照度計(jì)
美國(guó)Spectronics公司生產(chǎn)的SPECTROLINE AccuMAX™ 系列數(shù)字式紫外線(xiàn)及白光強(qiáng)度計(jì)的主要特性:
? 微處理控制的主機(jī)XF-1000(適用于測(cè)量燈管式紫外光源)及XR-1000(適用于燈泡型高壓汞燈式紫外光源),可通過(guò)可更換傳感器測(cè)量多種波長(zhǎng)紫外線(xiàn)強(qiáng)度及藍(lán)光和白光強(qiáng)度。
? 根據(jù)測(cè)量結(jié)果,自動(dòng)切換量程及顯示單位。
? 五個(gè)用戶(hù)可定義的設(shè)置及三個(gè)主菜單操作模式(數(shù)據(jù)/正常模式,自動(dòng)清零及積分),具有數(shù)據(jù)保持、峰值及返回功能。
? 紫外強(qiáng)度分辨率達(dá)1uw/cm2,全程精度優(yōu)于+/-5%,可溯源到NIST(美國(guó)國(guó)家計(jì)量院)標(biāo)準(zhǔn)
? 可顯示紫外照射劑量及照射時(shí)間內(nèi)的zui高強(qiáng)度及平均強(qiáng)度
? 的帶通干涉濾色片
? 可以將探測(cè)器直接連在主機(jī)上,或通過(guò)USB連線(xiàn)將探測(cè)器連到主機(jī)上
? 的余弦曲線(xiàn)反應(yīng)
? 用戶(hù)可定義的省電模式及自動(dòng)關(guān)機(jī)功能
? 兩節(jié)9V堿性電池工作(含)
? 大的,易于觀察的液晶顯示
? 密封傳感器外殼,及防水的USB連接器
? XF-1000主機(jī)外形尺寸(長(zhǎng)x 寬x 高): 7.75x 4.25x1.25英寸(19.7x10.8x3.2cm)
? 主機(jī)重量1.1磅(499克)
AccuMAX 系列強(qiáng)度計(jì)為的紫外線(xiàn)強(qiáng)度、劑量測(cè)量及可見(jiàn)光照度應(yīng)用而設(shè)計(jì)。通過(guò)選配可更換傳感器,可以測(cè)量紫外強(qiáng)度及紫外照射劑量(能量)。XR-1000及XF-1000主機(jī)為圓滑設(shè)計(jì),外殼結(jié)實(shí)。根據(jù)不同的測(cè)量結(jié)果,自動(dòng)選擇顯示單位,zui多顯示四位數(shù)值。顯示屏為3"液晶顯示,帶圖標(biāo)及數(shù)字顯示。主機(jī)外套有可拆的橡膠保護(hù)套。同時(shí)可選配手提箱。
主機(jī)型號(hào) | 出廠標(biāo)定 | |
XF-1000 | 為燈管式紫外光源標(biāo)定 | |
XR-1000 | 為高壓汞燈式燈泡光源標(biāo)定 | |
套裝XRP-3000黑白兩用照度計(jì)包括: · XR-1000主機(jī) · XDS-1000雙波長(zhǎng)傳感器,可同時(shí)測(cè)量UVA(黑光)強(qiáng)度及白光照度 · 手提箱 |
AccuMAX 傳感器滿(mǎn)足實(shí)驗(yàn)室及生物應(yīng)用要求。傳感器防水、具有密封外殼,高性能帶通濾色片及的余弦反應(yīng)。單波長(zhǎng)的傳感器可提供標(biāo)準(zhǔn)量程(XS系列)及特寬量程(XTS系列)。標(biāo)準(zhǔn)量程適傳感器適合于檢測(cè)管式及高壓汞燈泡式紫外光源,特寬量程適合于特高強(qiáng)度紫外光源如紫外固化及光催化應(yīng)用。同時(shí)可提供單波長(zhǎng)可見(jiàn)光傳感器(XS-555/I)及亮度傳感器(XS-555/L)。而且,還可提供雙波長(zhǎng)傳感器探測(cè)器XDS-1000,可同時(shí)測(cè)量長(zhǎng)波UVA紫外線(xiàn)強(qiáng)度及白光照度。所有傳感器可方便地直接和主機(jī)相連或通過(guò)USB連線(xiàn)和主機(jī)相連。如需要,可選配5英尺(1.5米)長(zhǎng)帶防水適配器的的USB連線(xiàn)(件號(hào)XCB-100)。
傳感器型號(hào) | 外形尺寸(長(zhǎng)x寬x高) | 凈重 |
單個(gè)傳感器 | 3.0x2.0x7/8" (7.6cmx5.1cmx2.2cm) | 2.4盎司(68克) |
亮度測(cè)量傳感器 | 3.0x2.1x3.2"(7.6cmx5.3cmx8.1cm) | 6.4盎司(181克) |
傳感器型號(hào) | 測(cè)量光源 | 峰值反應(yīng) | 量程 |
XS-254 | 短波UV-C紫外線(xiàn) | 254nm | 0-100mw/cm2 |
XTS-254 | 短波UV-C紫外線(xiàn) | 254nm | 0-3w/cm2 |
XS-300 | 中波UV-B紫外線(xiàn) | 300nm | 0-100mw/cm2 |
XTS-300 | 中波UV-B紫外線(xiàn) | 300nm | 0-3w/cm2 |
XS-365 | 長(zhǎng)波UV-A紫外線(xiàn) | 365nm | 0-100mw/cm2 |
XTS-365 | 長(zhǎng)波UV-A紫外線(xiàn) | 365nm | 0-3w/cm2 |
XS-405 | 藍(lán)光 | 405nm | 0-100mw/cm2 |
XTS-405 | 藍(lán)光 | 405nm | 0-3w/cm2 |
XS-450 | 藍(lán)光 | 450nm | 0-100mw/cm2 |
XTS-450 | 藍(lán)光 | 450nm | 0-3w/cm2 |
XS-555/l | 可見(jiàn)光 | 555nm | 0-5300 lux(勒克斯) |
XS-555/L | 可見(jiàn)光 | 555nm | 0-1,000,000cd/m2, |
XDS-1000 | 雙波長(zhǎng)傳感器: | 365nm | 0-100mw/cm2 |
? 四個(gè)按鈕便于輕松操作-直覺(jué)交互功能
? 菜單驅(qū)動(dòng),用戶(hù)可選設(shè)置:選擇測(cè)量顯示單位及背景顯示燈以適合運(yùn)行環(huán)境。
? 屏幕顯示儀器狀態(tài),電池電量水平,紫外線(xiàn)強(qiáng)度,波長(zhǎng)及當(dāng)前可提供的功能。
? 多功能控制主操作模式:數(shù)據(jù)/正常模式、自動(dòng)清零模式及積分模式。
? 附加特性(峰值、保持及黑屏)嵌入在主操作模式中。
? 積分(INTG)模式對(duì)一段時(shí)間內(nèi)照射到傳感器的紫外線(xiàn)強(qiáng)度進(jìn)行累積--對(duì)于紫外劑量/能量應(yīng)用特別有用。
美國(guó)AccuMAX SPECTROLINE XS-555/I可見(jiàn)光傳感器,白光照度檢測(cè)
AccuMAX 微處理器控制的軟件對(duì)用戶(hù)是關(guān)鍵-提供友好操作、*功能及的讀數(shù)。主機(jī)隔模面板上的四個(gè)壓敏按鈕提供多種*功能。軟件驅(qū)動(dòng)功能菜單使操作人員可以進(jìn)入三種主操作模式:數(shù)據(jù)/正常模式、自動(dòng)清零模式及積分模式。為了省電,除了積分模式,在其他所有模式下10分鐘沒(méi)有操作則自動(dòng)關(guān)機(jī)。而且, 軟件允許用戶(hù)定義紫外線(xiàn)強(qiáng)度顯示單位及液晶屏背景光設(shè)置。所有這些功能及其他可選功能通過(guò)軟件的主菜單及子菜單都可輕松進(jìn)入。
用戶(hù)定義設(shè)置
AccuMAX 為用戶(hù)提供方便的自動(dòng)紫外線(xiàn)強(qiáng)度顯示單位(uw/cm2,mw/cm2及w/cm2)。用戶(hù)也可以選擇及調(diào)整顯示對(duì)比度、背景光亮度及主動(dòng)和被動(dòng)運(yùn)行的時(shí)間間隔(有助于省時(shí)的功能)。除非主機(jī)處于低電量狀態(tài),否則所有的用戶(hù)可選參數(shù)將進(jìn)行保存便于將來(lái)操作使用。
操作模式
數(shù)據(jù)/正常模式
此模式將實(shí)時(shí)測(cè)量照射到傳感器上的全部紫外線(xiàn)強(qiáng)度。用戶(hù)可以?xún)鼋Y(jié)讀數(shù)及顯示數(shù)據(jù)。在正常模式下,PEAK功能將凍結(jié)并顯示記錄的zui高強(qiáng)度值。
自動(dòng)清零
在此模式下,AccuMax強(qiáng)度計(jì)自動(dòng)減去"不想要的"環(huán)境光,所有測(cè)量的讀數(shù)為相對(duì)于環(huán)境光的讀數(shù)。保護(hù)用戶(hù)數(shù)據(jù)-記錄也由此模式進(jìn)入。.
積分(INTG)
在積分模式,儀器將照射到傳感器上的紫外線(xiàn)進(jìn)行累計(jì),之后顯示吸收的總紫外能量(單位為焦耳/cm2)。在此模式下,F(xiàn)reeze凍結(jié)功能將所顯示的過(guò)程保持在背景。為了方便操作,在積分模式,AccuMax將不自動(dòng)關(guān)機(jī),以便用戶(hù)可以連續(xù)長(zhǎng)時(shí)間測(cè)量紫外線(xiàn)劑量。
AccuMax 主機(jī)規(guī)格 | |
分辨率 | 根據(jù)測(cè)量值顯示單位自動(dòng)切換 |
白光 | 0.01 lux (測(cè)量值為0-29.99 Lux時(shí)) |
紫外線(xiàn) | 1 uw/cm2 (測(cè)量值為0-9999 uw/cm2時(shí)) |
屏幕 | 2.8" 液晶顯示 128x64像素 單色 |
采樣率 | 7.5Hz (單個(gè)傳感器時(shí))15Hz (雙傳感器時(shí)) |
讀數(shù)更新 | 2Hz |
全程精度 | 優(yōu)于±5%,按NIST(美國(guó)國(guó)家計(jì)量院)標(biāo)準(zhǔn) |
溫度系數(shù) | ±0.025%/°C (0-50°C) |
的英文介紹:
AccuMAX™ Series for Laboratory
Digital Microprocessor-Controlled Meters
Features two advanced digital, microprocessor-controlled readout units (XF-1000 for fluorescent UV tubes; XR-1000 for HID UV bulbs) specially calibrated to complement a full line of interchangeable AccuMAX series sensor detectors
Software-driven functions provide multifaceted light level reading
User-selectable, multilingual display settings. Choose from English, French, German and Spanish.
Five user-customized settings and three main operation modes (absolute data/normal, autozeroing and integration) featuring hold, peak and back functions
Overall accuracy of better than ±5% with reference to NIST standards
Superior bandpass interference filter resists degradation and prevents undesirable radiation readings
Excellent linearity and cosine response
Choice of direct or USB cable connection between sensor detector and readout unit (XCB-50 USB cable included)
Large, easy-to-read monochrome LCD screen
Automatic shutoff and user-defined power save features
Powered by two 9-volt alkaline batteries (included)
Readout unit dimensions (W x L x H) : 4.25 in x 7.75 in x 1.25 in, 10.8 cm x 19.7 cm x 3.2 cm)
Readout unit weight: 1.1 lb (499 g)
The AccuMAX series is designed to provide accurate readouts for UV irradiance, visible illuminance or luminance light readings. When equipped with an interchangeable sensor detector, the AccuMAX readout unit can be used to perform fluorescent inspection (intensity check through normal operation) and UV dosing (energy check through integration operation). Both the XR-1000 and XF-1000 readout units feature a sleek design and rugged housing, maximum 4-digit autoranging and easy-to-read 3 inch monochrome LCD screen with icons and alphanumeric display. A removable, rubber protective boot for the meter is included. A padded carrying case is available as an accessory.
MODEL | READOUT UNIT |
XF-1000 | Calibrated for fluorescent UV tubes |
XR-1000 | Calibrated for HID UV bulbs |
Four side-by-side buttons provide for easy operation of user-intuitive interactive functions
Menu-driven, user-selectable settings; customized visible units of measurement and backlight display to suit operating conditions
Screen displays meter status, battery power level, light intensity, wave type readings and user-available functions
Multiple-function control of main operational modes: absolute data/normal, autozeroing and integration
Multifaceted light level reading and access to additional features (peak, hold and back screen) embedded within main operational modes
Integration (INTG) mode sums up cumulative ultraviolet light exposed to sensor over an interval of time – useful for UV dosing applications
The AccuMAX meter’s microprocessor-controlled software is the key to its user-friendly operation, advanced functionality and accurate readouts. Four pressure-sensitive buttons on the readout unit’s membrane keypad offer an extensive array of advanced features. The software-driven function menu gives full access to the three main operating modes: absolute data/normal, automatic zero and integration. To save battery power, the meter automatically shuts off after 10 minutes of non-use in all modes, with the exception of integration. In addition, the software allows the user to customize units of measurement for visible light readouts, as well as LCD screen backlight settings. These functions and other user-selectable parameters are easily accessible though the software’s main and subordinate menus.
Customizing Settings
The AccuMAX provides users the capability of selecting the default visible unit of measurement in their choice of foot-candles (fc), lux, lm/ft2 or lm/m2. The user can also select and adjust the display contrast, backlight brightness and interval between active and passive operations, which also helps conserve battery power. Unless the meter is at low-battery status, all user-selectable parameters will be saved and used for future meter operations.
Operational Modes
Absolute Data/Normal
This mode will measure the real-time absolute total light to which the sensor is exposed. The HOLD function is accessible in this mode, giving the user the option to freeze the reading and display the data. The PEAK feature is also available in this mode, which will freeze and display the highest intensity reading recorded during normal operation.
Automatic Zero
In this mode, the AccuMAX automatically subtracts “unwanted" ambient light when measuring light output. All subsequent measurement readings will be relative to this zero light level, saving the user data-recording time. The HOLD and PEAK features are also accessible in this mode.
Integration (INTG)
In the integration mode, the meter sums up the cumulative ultraviolet light that the sensor is exposed to over an interval of time, then displays the resultant total energy absorbed in joules. This mode is useful for UV dosing applications when checking energy levels of the light source used. In this mode, the freeze feature will hold the displayed data static while continuing the integration process in the background. For convenience, the AccuMAX will not shut off automatically after 10 minutes (as it would in other functions), allowing the user to continue integrating for extended periods of time.
Sensor Detectors
AccuMAX sensor detectors are designed to meet virtually any laboratory or life science application. These detectors feature water-resistant, sealed sensor housings, superior bandpass interference filters and excellent cosine response. Single-wavelength detectors are available in both standard range (XS-series), ideal for checking the intensity of fluorescent UV tubes and HID UV bulbs, and extended range (XTS-series), useful for high-intensity light sources used in curing and photoactivation applications. Also available are a single-wavelength visible illuminance detector (XS-555/I) and a luminance detector (XS-555/L). All sensors can easily be connected to the readout unit either directly or with a standard USB cable. A special 5 foot USB cable with water-resistant adapter (XCB-100) is available as an accessory.
MODEL | DIMENSIONS (L x W x H) | NET WEIGHT |
Single Sensor | 2.0 in x 3.0 in x 7/8, (5.1 x 7.6 x 2.2cm) | 2.4 oz, 68g |
Luminance Sensor | 2.1 in x 3.0 in x 3.2 in, (5.3 x 7.6 x 8.1cm) | 6.4 oz, 181g |
MODEL | SENSORS | SPECTRAL RANGE | RANGE IN UNITS |
XS-254 | UV-C | 254nm | 0-100 mW/cm2 |
XTS-254 | UV-C | 254nm | 0-3W/cm2 |
XS-300 | UV-B | 300nm | 0-100 mW/cm2 |
XTS-300 | UV-B | 300nm | 0-3W/cm2 |
XS-365 | UV-A | 365nm | 0-100 mW/cm2 |
XTS-365 | UV-A | 365nm | 0-3W/cm2 |
XS-405 | UV-V | 405nm | 0-100 mW/cm2 |
XTS-405 | UV-V | 405nm | 0-3W/cm2 |
XS-450 | Bilirubin | 450nm | 0-100 mW/cm2 |
XTS-450 | Bilirubin | 450nm | 0-3W/cm2 |
XS-555/I | Visible illuminance | 555nm | 0-5,300 lux, 0-500 fc |
XS-555/L | Visible illuminance | 555nm | 0-1,000,000 cd/m2, 0-90,000 cd/ft2, 0-285,000 fL |
READOUT UNIT (XR-1000) | |
Resolution | 4-digit autoranging display |
Sample Rate | 7.5 Hz (single sensor) |
Read Update | 2 Hz |
Overall Accuracy | Better than + 5% with reference to NIST standards |
Temperature Coefficient | ±0.025%/°C (0 to 50°C) |
Power Requirements | Two 9V alkaline batteries (included) |
Dimensions | |
Length | 7.75 in (19.7 cm) |
Width | 4.25 in (10.8 cm) |
Thickness | 1.25 in (3.2 cm) |
Weight | 0.8 lb (360 g) |
XRP-3000 AccuMAX™ for NDT
Advanced Digital Radiometer/Photometer Kit
Single detector with dual sensors measures both ultraviolet and visible light. Complies with ASTM specifications for MPI and FPI. Specially engineered for NDT applications.
Dual UV-A/Visible Sensor Detector (XDS-1000) | ||
UV-A Sensor Visible Sensor | Measurement Range 0–100 mW/cm2 0–5,300 lux (0-500 fc) | Spectral Range 320-400 nm 460-675 nm |